PD-169 Issue 3B Installation Guide Page 54 of 56
Diagram 14 – ACT Proximity Fob system interconnections
ACTPro1000/2000/3000 Proximity Access Controller
ACTPro100/200 Proximity Door Extender
Notes
1. Connect the lock release or Maglock using the ACT Manuals.
2. Leave the BSD-DIG controller set to Fail Secure regardless of the type of release used.
3. A normally open exit button can still be fitted to the ACT controller in addition to the
Digibell wiring.
4. If the 2 units are not sharing a power supply, then a connection from BSD-DIG controller
12V - to ACT 0V will be required.
5. Look for the notes on the ACT installation diagram concerning the use of links when the
door contact is not used and when a power supply without power fail is not used.